Tender

SUPPLY AND DELIVERY OF HV TRANSFORMER CONDITION MONITORING AND TEST EQUIPMENT

Type
Tender
Issuer / source
PRAZ eGP — ZIMBABWE POWER COMPANY
Closing date
15 December 2026
Location
Zimbabwe
Category
Electrical Products: Cables and Materials, Power Back-Up Equipment, Transformers, Standby Generators, Consumables & Accessories
Listed
22 November 2026

Create a free Infoden account to open the original listing, then apply directly with the issuer.

About this opportunity

HV TRANSFORMER CONDITION MONITORING AND TEST EQUIPMENT Reference: ZPC/HO/DOM 122/2026 · Procuring entity: ZIMBABWE POWER COMPANY · Scope: Open · Published: 2026-11-18 • Portable DGA Analyser Compact portable system that is designed for laboratory quality Dissolved Gas Analysis (DGA) on manually taken samples from transformers filled with mineral oil and ester fluids. Photo-Acoustic Spectroscopy (PAS) measurement technology, providing laboratory challenging levels of precision and repeatability with no consumables and no need for frequent re-calibration. Measuring Range Hydrogen (H₂) 5 – 5,000 ppm, Carbon Monoxide (CO) 2 – 50,000 ppm, Carbon Dioxide (CO₂) 40 – 50,000 ppm, Methane (CH₄) 2 – 50,000 ppm, Acetylene (C₂H₂) 0.5 – 50,000 ppm, Ethane (C₂H₆) 2 – 50,000 ppm, Ethylene (C₂H₄) 2 – 50,000 ppm, Measurement Accuracy ±5% or ±LDL (whichever is greater), Moisture (H₂O) 0-100% relative humidity, Moisture in Oil Accuracy ±3% Fast onsite diagnostics in less than 30 minutes Compatible with mineral insulating oils and newer ester-based fluids (natural and synthetic) Calibration and consumable gas free design for autonomous field operation. — 1 Each (testing) • Mobile Transformer oil Filtration unit Flow rate L/min 250 Working vacuum Pa ≤133 Limited vacuum Pa ≤5 Working Pressure MPa ≤0.4 Temperature range ℃ 20 ~80 Power 380V 50HZ (customized) Noise dB(A) ≤65~80( depend on the configuration ) Fault free working hours h ≥4000 Continuous working hours h ≥150 Heating power kW 168 Total power kW 182 Inlet (Outlet) diameter mm Φ60 Weight kg 2000 After Filtration Breakdown voltage kV ≥75 Water content ppm ≤3 Medium consumption tgδ(90℃ % ≤0.3 Acid value mgKOH/g ≤0.03 Gas content % ≤0.1 Filtration precision μm ≤3(customized) Features Processing Capacity 250L/min (up to 15000L/h) Vacuum Degree ≤ -0.098 MPa Working Temperature 80-300°C (adjustable) Filtration Precision ≤ 1µm Water Content After Treatment ≤ 50 ppm Acid Value After Treatment ≤ 0.03 mgKOH/g Gas Content After Treatment ≤ 0.1% Final Oil Quality Colour index ≤ 1.5, Flashpoint restored, Viscosity stabilized More Technical Specifications (further spec in SBD) — 1 Each (testing) • Industrial Ultrasound/Acoustic Imaging Camera for Partial Discharge Detection, Pressurized Leak Detection and Mechanical Fault Detection Acoustic Measurement 124 low-noise MEMS microphones, real-time sound visualization Severity Assessment Automatic AI-based severity assessment including recommended actions on board camera Distance From 0.3 m (1.0 ft) up to 200 m (656 ft) Leak Rate 0.0032 l/min from 2.5 m (8.2 ft), 0.0044 l/min from 6 m (19.6 ft) Camera software update Automatic Over the Air (OTA) wireless update or via USB connection Field of view (FOV) 75° diagonal Video Frame Rate Camera 60 fps / Acoustic image 30 fps / Screen 70 fps Video Image Resolution 1280 × 720 Acoustic Measurement 124 low-noise MEMS microphones, real-time sound visualization Detects Following Gases Detects all gases provided they are under sufficient pressure. Quantifies leak rate costs for compressed air, ammonia, argon, CO₂, helium, hydrogen, methane, natural gas, and nitrogen.(More spec in S.B.D) — 1 Each (testing)

Listed by Infoden Consultancy for information. Always confirm the closing date, documents and eligibility on the issuer's original notice.

More tenders · Grants & funding · PRAZ registration · Tax clearance